<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Válvula de disparo | Materialespro</title>
	<atom:link href="https://materialespro.com.ar/etiqueta-producto/valvula-de-disparo/feed/" rel="self" type="application/rss+xml" />
	<link>https://materialespro.com.ar</link>
	<description>14 años de experiencia</description>
	<lastBuildDate>Thu, 30 Jul 2026 21:53:21 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.2</generator>

<image>
	<url>https://materialespro.com.ar/wp-content/uploads/2017/05/cropped-favicon-1-32x32.png</url>
	<title>Válvula de disparo | Materialespro</title>
	<link>https://materialespro.com.ar</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Válvula de Disparo para Instalaciones Fijas de CO₂ y FM-200 – Accionamiento Manual, Eléctrico y Neumático</title>
		<link>https://materialespro.com.ar/producto/valvula-de-disparo-para-instalaciones-fijas-de-co%e2%82%82-y-fm-200-accionamiento-manual-electrico-y-neumatico/</link>
					<comments>https://materialespro.com.ar/producto/valvula-de-disparo-para-instalaciones-fijas-de-co%e2%82%82-y-fm-200-accionamiento-manual-electrico-y-neumatico/#respond</comments>
		
		<dc:creator><![CDATA[Dario Touceda]]></dc:creator>
		<pubDate>Thu, 30 Jul 2026 21:42:15 +0000</pubDate>
				<guid isPermaLink="false">https://materialespro.com.ar/?post_type=product&#038;p=3160</guid>

					<description><![CDATA[<p>La <strong data-start="637" data-end="700">válvula de disparo para instalaciones fijas de CO₂ y FM-200</strong> está diseñada para activar sistemas automáticos de extinción por agentes limpios. Fabricada en <strong data-start="796" data-end="814">bronce forjado</strong>, ofrece alta resistencia mecánica y permite <strong data-start="859" data-end="925">accionamiento manual, eléctrico mediante solenoide o neumático</strong>, adaptándose a diferentes configuraciones de sistemas contra incendios.</p>
The post <a href="https://materialespro.com.ar/producto/valvula-de-disparo-para-instalaciones-fijas-de-co%e2%82%82-y-fm-200-accionamiento-manual-electrico-y-neumatico/">Válvula de Disparo para Instalaciones Fijas de CO₂ y FM-200 – Accionamiento Manual, Eléctrico y Neumático</a> first appeared on <a href="https://materialespro.com.ar">Materialespro</a>.]]></description>
										<content:encoded><![CDATA[<p data-start="1025" data-end="1259">La válvula de disparo constituye uno de los componentes principales en los sistemas fijos de extinción por <strong data-start="1132" data-end="1139">CO₂</strong> y <strong data-start="1142" data-end="1152">FM-200</strong>, permitiendo la liberación controlada del agente extintor cuando el sistema recibe la orden de activación.</p>
<p data-start="1261" data-end="1428">Su cuerpo construido en <strong data-start="1285" data-end="1303">bronce forjado</strong> proporciona una excelente resistencia a la corrosión y una larga vida útil, incluso en instalaciones industriales exigentes.</p>
<p data-start="1430" data-end="1652">Gracias a sus diferentes opciones de accionamiento, puede integrarse tanto en sistemas manuales como totalmente automáticos, permitiendo además la interconexión con otras válvulas esclavas mediante accionamiento neumático.</p>
<p data-start="1654" data-end="1871">Es una solución ampliamente utilizada en salas eléctricas, centros de datos, salas de máquinas, industrias, depósitos, salas de bombas y todo ambiente protegido mediante sistemas automáticos de supresión de incendios.</p>
<hr data-start="1873" data-end="1876" />
<h3 data-section-id="k1ohk1" data-start="1878" data-end="1907">Características principales</h3>
<ul data-start="1909" data-end="2284">
<li data-section-id="ijn8af" data-start="1909" data-end="1942">Construcción en bronce forjado.</li>
<li data-section-id="12rtb7o" data-start="1943" data-end="1996">Alta confiabilidad para sistemas de extinción fija.</li>
<li data-section-id="1wq6ru7" data-start="1997" data-end="2037">Accionamiento manual mediante gatillo.</li>
<li data-section-id="15glc59" data-start="2038" data-end="2083">Accionamiento eléctrico mediante solenoide.</li>
<li data-section-id="uye1gx" data-start="2084" data-end="2140">Accionamiento neumático para sistemas interconectados.</li>
<li data-section-id="1u45vn1" data-start="2141" data-end="2178">Diseño robusto para uso industrial.</li>
<li data-section-id="uzrrzl" data-start="2179" data-end="2226">Compatible con instalaciones de CO₂ y FM-200.</li>
<li data-section-id="kexhui" data-start="2227" data-end="2284">Fácil integración con sistemas automáticos de incendio.</li>
</ul>
<hr data-start="2286" data-end="2289" />
<h3 data-section-id="bf1gc7" data-start="2291" data-end="2318">Especificaciones técnicas</h3>
<ul data-start="2320" data-end="2732">
<li data-section-id="b0cofu" data-start="2320" data-end="2380"><strong data-start="2322" data-end="2335">Producto:</strong> Válvula de disparo para instalaciones fijas.</li>
<li data-section-id="efvd7f" data-start="2381" data-end="2412"><strong data-start="2383" data-end="2396">Material:</strong> Bronce forjado.</li>
<li data-section-id="1vahl83" data-start="2413" data-end="2436"><strong data-start="2415" data-end="2427">Entrada:</strong> 1&#8243; BSPT.</li>
<li data-section-id="1f3j39k" data-start="2437" data-end="2459"><strong data-start="2439" data-end="2450">Salida:</strong> 1/2&#8243; NF.</li>
<li data-section-id="1mjvr6s" data-start="2460" data-end="2496"><strong data-start="2462" data-end="2484">Presión de prueba:</strong> 250 kg/cm².</li>
<li data-section-id="sh482e" data-start="2497" data-end="2538"><strong data-start="2499" data-end="2522">Disco de seguridad:</strong> 180–200 kg/cm².</li>
<li data-section-id="op0hit" data-start="2539" data-end="2584"><strong data-start="2541" data-end="2566">Accionamiento manual:</strong> Mediante gatillo.</li>
<li data-section-id="1otoi1n" data-start="2585" data-end="2656"><strong data-start="2587" data-end="2615">Accionamiento eléctrico:</strong> Solenoide 12 / 24 / 110 / 220 VCC o VCA.</li>
<li data-section-id="18n0qm6" data-start="2657" data-end="2732"><strong data-start="2659" data-end="2687">Accionamiento neumático:</strong> Sí, permite interconectar válvulas esclavas.</li>
</ul>
<hr data-start="2734" data-end="2737" />
<h3 data-section-id="13k8s98" data-start="2739" data-end="2763">Accesorios compatibles</h3>
<ul data-start="2765" data-end="2975">
<li data-section-id="1nnx3dg" data-start="2765" data-end="2795">Solenoides de accionamiento.</li>
<li data-section-id="z3zr4y" data-start="2796" data-end="2815">Cilindros de CO₂.</li>
<li data-section-id="1gx6ws4" data-start="2816" data-end="2837">Sistemas de FM-200.</li>
<li data-section-id="1yrkdhm" data-start="2838" data-end="2866">Mangueras de alta presión.</li>
<li data-section-id="11lw8je" data-start="2867" data-end="2892">Colectores de descarga.</li>
<li data-section-id="ucqzhh" data-start="2893" data-end="2906">Manómetros.</li>
<li data-section-id="qr30ws" data-start="2907" data-end="2927">Válvulas esclavas.</li>
<li data-section-id="14xxhp7" data-start="2928" data-end="2975">Componentes para sistemas fijos de extinción.</li>
</ul>
<hr data-start="2977" data-end="2980" />
<h3 data-section-id="qub0z1" data-start="2982" data-end="2996">Aplicaciones</h3>
<ul data-start="2998" data-end="3234">
<li data-section-id="1ehq5br" data-start="2998" data-end="3022">Sistemas fijos de CO₂.</li>
<li data-section-id="1y0qryl" data-start="3023" data-end="3054">Sistemas de extinción FM-200.</li>
<li data-section-id="xv8apk" data-start="3055" data-end="3074">Centros de datos.</li>
<li data-section-id="v57q53" data-start="3075" data-end="3094">Salas eléctricas.</li>
<li data-section-id="1fnz55n" data-start="3095" data-end="3115">Salas de tableros.</li>
<li data-section-id="ydzy5a" data-start="3116" data-end="3129">Industrias.</li>
<li data-section-id="17ti8qe" data-start="3130" data-end="3150">Salas de máquinas.</li>
<li data-section-id="1eyv676" data-start="3151" data-end="3174">Plantas industriales.</li>
<li data-section-id="1ybfyze" data-start="3175" data-end="3234">Instalaciones con protección automática contra incendios.</li>
</ul>
<hr data-start="3236" data-end="3239" />
<h3 data-section-id="werakz" data-start="3241" data-end="3253">Beneficios</h3>
<ul data-start="3255" data-end="3566">
<li data-section-id="13yvc9v" data-start="3255" data-end="3282">Alta seguridad operativa.</li>
<li data-section-id="asdu8e" data-start="3283" data-end="3316">Excelente resistencia mecánica.</li>
<li data-section-id="1h6bhv2" data-start="3317" data-end="3335">Larga vida útil.</li>
<li data-section-id="19yw81q" data-start="3336" data-end="3385">Compatible con distintos métodos de activación.</li>
<li data-section-id="pukn53" data-start="3386" data-end="3443">Fácil integración en instalaciones nuevas o existentes.</li>
<li data-section-id="1v28het" data-start="3444" data-end="3497">Ideal para aplicaciones industriales y comerciales.</li>
<li data-section-id="86s3r4" data-start="3498" data-end="3519">Bajo mantenimiento.</li>
<li data-section-id="yjvycl" data-start="3520" data-end="3566">Fabricación preparada para trabajo continuo.</li>
</ul>The post <a href="https://materialespro.com.ar/producto/valvula-de-disparo-para-instalaciones-fijas-de-co%e2%82%82-y-fm-200-accionamiento-manual-electrico-y-neumatico/">Válvula de Disparo para Instalaciones Fijas de CO₂ y FM-200 – Accionamiento Manual, Eléctrico y Neumático</a> first appeared on <a href="https://materialespro.com.ar">Materialespro</a>.]]></content:encoded>
					
					<wfw:commentRss>https://materialespro.com.ar/producto/valvula-de-disparo-para-instalaciones-fijas-de-co%e2%82%82-y-fm-200-accionamiento-manual-electrico-y-neumatico/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>